Octax Laser & imaging systems

Description Modular laser systems for applications in IVF

Log in to purchase

Octax LaserShot™ M

  • Description: Microsurgical Laser system, complete with infrared laser module, microscope adaptor, mirror block, laser lens 25x, Octax USB2 digital camera 3.2 Mpix, EyeWare software, single foot switch, manual; complying with MDR 2017/745 for CE marked inverted microscopes
  • Purpose: For use in laser applications within IVF, including assisted hatching, sperm viability testing, blastomere, polar body and trophectoderm biopsy and also blastocyst collapsing prior to vitrification.

Disclaimer: For US users: Indications for use of the LaserShot M and NaviLase device, as registered with the FDA: For use in assisted reproduction procedures to ablate or thin the zona pellucida of an embryo to facilitate assisted hatching or recovery of cells for pre-implantation genetic diagnosis (blastomeres). The device can also be used on blastocyst stage embryos for biopsy of trophectoderm cells for pre-implantation diagnosis procedures, and blastocyst collapse prior to vitrification procedures.

Octax NaviLase®

  • Description: Dynamic multi-purpose laser system for ART., complete with calibration free and moveable infrared laser module incl. motion elements, microscope adaptor, mirror block, laser lens 25x, Octax USB2 digital camera 3.2 Mpix, EyeWare software, single foot switch, manual; MDR 2017/745 compliant for CE marked inverted microscopes
  • Purpose: For use in laser applications within IVF, including assisted hatching, sperm viability testing, blastomere, polar body and trophectoderm biopsy and also blastocyst collapsing prior to vitrification.

Disclaimer: For US users: Indications for use of the LaserShot M and NaviLase device, as registered with the FDA: For use in assisted reproduction procedures to ablate or thin the zona pellucida of an embryo to facilitate assisted hatching or recovery of cells for pre-implantation genetic diagnosis (blastomeres). The device can also be used on blastocyst stage embryos for biopsy of trophectoderm cells for pre-implantation diagnosis procedures, and blastocyst collapse prior to vitrification procedures.

Octax NaviLase® Upgrade

  • Description: Upgrade for existing Octax LaserShot™ system installed to modern inverted microscopes.

Octax Target Pointer

  • Description: Upgrade for Octax LaserShot™ and Octax NaviLase™ systems.

Disclaimer: Not for sale in US

Octax single foot switch

  • Description: For laser release.

DELL Optiplex PC

  • Description: PC suitable for Octax laser systems, incl. 22” full HD monitor.

Safe, efficient and easy to use

Modular laser systems for applications in IVF

 

Octax is more than just a laser; it is a multipurpose platform for digital imaging, image analysis and advanced applications in assisted reproduction. The static Octax LaserShot and the dynamic Octax NaviLase provide excellent image quality and safe procedures. Both lasers are calibration free and they can be used for laser applications within IVF*, including:

  • Assisted hatching/assisted thinning
  • Trophectoderm, blastomere biopsy
  • Blastocyst collapsing
  • Sperm viability testing

*Some applications are country specific approved laser applications option.

Which laser is right for you?

Being modular and flexible, Octax adapts to your specific needs and preferences. Depending on your need we offer a dynamic laser - Octax NaviLase and a static laser - Octax LaserShot. Both offer the same outstanding image quality and additional components to compose the best option for your lab.

Download system specifications

Dynamic laser - Octax NaviLase

When using NaviLase, the embryo remains in place while the laser is directed to the chosen target site. You can make several shots along a straight or curved line.

Multi-pulse in a curved line (zona thinning)

 

Multi-pulse in a straight line (eg. opening zona for biopsy)

1-3 pulse option for supporting cell separation (for troph­ecto­derm biopsy)

Static laser - Octax LaserShot

When using Octax LaserShot, the laser target site is fixed and embryo is aligned with the laser target site.

 

Biopsy demonstration

Watch Nuno Costa-Borges from Embryotools SL demonstrates the technique in blastocyst biopsy with Octax NaviLase.

Safe since the start

Proven in more than 100 scientific publications

With tens of thousands of children born after laser treatment and with no adverse effects, you can be sure your gametes* and embryos are safe during laser procedures performed using Octax lasers. Octax laser technology has been tried and tested in over 100 preclinical and clinical publications, which have shown zero adverse effects on oocytes*, embryos or the children born after laser treatment.

  • No alterations of the cytoplasm. Histology on mouse oocytes after laser treatment. (Germond et al., 1995)
  • No thermal damage observed. SEM analysis of the zona pellucida after laser treatmentof mouse zygotes. (Rink et al., 1996)
  • No genetic, histological or anatomical effects. Transfer of mouse zygotes into foster mothers after laser treatment, immunohistochemical/anatomical analysis of the offspring, breeding for another two generations. (Germond et al., 1996)
  • No increase in chromosomal aberrations and congenital malformations. Follow-up study on 134 one-year-old children after laser-assisted hatching (LAH) as compared to controls without LAH. (Kanyo & Konc, 2003)

*Some applications are country specific approved laser applications option.

Download list of publications

Software known for its user friendliness

The core element for the laser and imaging systems is the Octax EyeWare software, which operates the laser, takes images and records videos. This multipurpose imaging and archiving software is designed to be highly intuitive, making it easy to learn and use. The navigation is logical and menus are clear and straightforward. All functions are easy to access, saving time and increasing safety. 

The software is based on an SQL server and can support installations ranging from a stand-alone imaging station to a multi-operational, multi-user networked system

Flexible with multiple upgrading options

 

Octax EyeWare is unique in its seamless integration of additional software, with no need for multiple databases.

  • High-resolution live video display
  • Unlimited image snapshot gallery
  • Instant access to objective calibrations
  • Image and video capture and storage function
  • Multi-camera support
  • Measurement tools
  • Multilingual GUI
  • Comparison option for up to four images at a time
  • Image zoom function

Octax laser components

Octax Eye USB2 digital video camera

  • Up to 30 fps depending on resolution
  • Complete with space saving 90 degree connector USB cable and device driver
  • 3.2 Mpix - 2048 x 1536 pixels, true color, high resolution camera with integrated hardware zoom function

Octax Target pointer

  • Octax TargetPointer, optional add-on for trophectoderm biopsy, indicates laser target through microscope eyepieces. 
  • For Olympus IX 50/70, IX 51/71/81, IX 53/73, Nikon TE2000 & Ti, Leica DMIRB, DMI 3000, Zeiss Axiovert 200 & Axio Observer

Octax single foot switch

  • Octax single foot switch for triggering the laser.

How to secure precision and improve workflows in laser procedures 

Lab Director and co-owner Dr. Oliver Sterthaus at Fertisuisse in Switzerland built a completely new IVF clinic in 2014 with his colleagues. When setting up the new lab, convenience and workflow were important factors, and therefore they decided to use the dynamic Octax NaviLase laser system for all laser procedures.

Watch Dr. Oliver Sterthaus story here.

Support Documents

Documents Language

Octax Laser & imaging systems

Product manuals

English

Octax LaserShot M™ Octax NaviLase® User Manual

Document and Ref: Version 7.2, 2023-11/English

Disclaimer: This manual is only valid for MDR lasers. Not valid in the US.
Octax Laser & imaging systems

Product manuals

English

Octax LaserShot M™ Octax NaviLase® User Manual

Document and Ref: Version 6, 2023-02-13//English (US)

Disclaimer: This manual is only valid for FDA lasers.
Octax Laser & imaging systems

Product manuals

German

Octax LaserShot M™ Octax NaviLase® User Manual

Document and Ref: Version 7.2, 2023-11/German

Disclaimer: This manual is only valid for MDR lasers. Not valid in the US.
Octax Laser & imaging systems

Product manuals

French

Octax LaserShot MTM Octax NaviLase® User Manual French

Document and Ref: Version 7.2, 2023-11/French

Disclaimer: This manual is only valid for MDR lasers. Not valid in the US.
Octax Laser & imaging systems

Product manuals

Polish

Octax LaserShot M™ Octax NaviLase® User Manual

Document and Ref: Version 7.2, 2023-11/Polish

Disclaimer: This manual is only valid for MDR lasers. Not valid in the US.
Octax Laser & imaging systems

Product manuals

Dutch

Octax LaserShot M™ Octax NaviLase® User Manual

Document and Ref: Version 7.2 2023-11/Dutch

Disclaimer: This manual is only valid for MDR lasers. Not valid in the US.
Octax Laser & imaging systems

Product manuals

Italian

Octax LaserShot M™ Octax NaviLase® User Manual

Document and Ref: Version 7.2, 2023-11/Italian

Disclaimer: This manual is only valid for MDR lasers. Not valid in the US.
Octax Laser & imaging systems

Product manuals

Hungarian

Octax LaserShot MTM Octax NaviLase® User Manual Hungarian

Document and Ref: Version 7.2, 2023-11/Hungarian

Disclaimer: This manual is only valid for MDR lasers. Not valid in the US.
Octax Laser & imaging systems

Product manuals

Spanish

Octax LaserShot M™ Octax NaviLase® User Manual

Document and Ref: Version 7.2, revised 2023.11/Spanish

Disclaimer: This manual is only valid for MDR lasers. Not valid in the US.
Octax Laser & imaging systems

Product manuals

Greek

Octax LaserShot M™ Octax NaviLase® User Manual

Document and Ref: Version 7.2, 2023-11/Greek

Disclaimer: This manual is only valid for MDR lasers. Not valid in the US.
Octax Laser & imaging systems

Product manuals

Czech

Octax LaserShot M™ Octax NaviLase® User Manual

Document and Ref: Version 7.2, 2023-11/Czech.

Disclaimer: This manual is only valid for MDR lasers.
Octax Laser & imaging systems

Technotes

English

Octax laser blastocyst collapsing

Document and Ref: Octax laser blastocyst collapsing, Vitrolife, v1, September 2016. This technote explains how to use Octax lasers in blastocyst collapsing.

Octax Laser & imaging systems

Technotes

English

Sperm viability testing using Octax laser

Document and Ref: Sperm viability testing using Octax laser, Vitrolife, v2, January 2018. This technote explains how to use Octax lasers for sperm viability testing.

Octax Laser & imaging systems

Technotes

English

Trophectoderm biopsy for PGD & PGS using Octax Laser Shot or Octax NaviLase

Document and Ref: Trophectoderm biopsy for PGD & PGS using Octax Laser Shot or Octax NaviLase, Vitrolife, v1 INT, September 2016. This technote explains how to use Octax lasers for trophectoderm biopsy.

Do you have a question about this product?

Contact us


Please add your professional email address.



Vitrolife needs the contact information you provide to us to contact you about our products and services. You may unsubscribe from these communications at anytime. For information on how to unsubscribe, as well as our privacy practices and commitment to protecting your privacy, check out our Privacy Policy.
Hidden




Find your local Vitrolife representative

Contact us

Maximise success every step of the way

We provide what you need to secure improved results throughout the IVF journey.